Anesthetic apparatus:
Features:
1. The first Chinese anaesthesia workstation
2. SIMV mode with flow-trigger
3. Independent 10.4 screen, flexible monitoring angle
4. CE marked, meet clinical safety requirement of EU
5. Advanced electromagnetic valve ensures accurate tidal volume and compensation
6. Parameters monitored: P-T, F-T, V-T waveforms & P-V, F-V loops
Technical Specification
Physical & Environmental Specification
. Dimensions (WxHxD): 800x1300x630mm
. Weight: 100kg (Basic unit)
. Storage temperature: -10~+60°C
. Working temperature: +10~+40°C
. Storage humidity:≤95%
Electrical Specification
. Main power: 100-240VA C, 50-60Hz
. Battery: 24VDC, minimum 120 min
. Power consumption:≤70W
Pneumatic Specification
Flowmeters:
O2: 0-1L/min; 1-10l/min
N2O:0-1L/min; 1-10L/min
AIR: 0-1L/min; 1-12L/min
Auxiliary O2 Range: 0-12L/min
. Gas system: O2 supply failure alarm
O2 supply failure protection
O2 flush: 35-75L/min
. Working mode: Closed, Semi-closed, Semi-open
. Driven mode: Pneumatically driven and electronically controlled
. Operating mode: Man. / Vent.
. Safety valve:≤8kpa
Ventilator Specification
. Patient type: Adult, pediatric
. Ventilation modes: IPPV, PCV, SIMV+PS , PS and Manual
. Setting: Touch key & navigator wheel knob
. Tidal volume: 20-1500ml
. Ventilation frequency: 4-100bmp
. I:E ratio: 4:1-1:8
. Pressure control: 5-70cmH2O
. Ppeep: 3-50cmH2O
. Inspiratory plateau: 0-60%Ti
. Trigger sensitivity: 1-15L/min
. Monitoring Display: 10.4TFT color screen
Graph display: P-T, F-T, P-V, F-V and optioanl CO2-T
. Alarm: Pressure: Paw, high/low limit
Volumes: MV high/low limit
High limit of breath rate
Gas: FiO2 high/low limit
Low O2 supply pressure
Airway malfunction
Power failure
Vaporizer
. Support 2 vaporizer (Selectatec compatible)
Agent type: Halothane, Enflurane, Isoflurane, Sevoflulrane available
Aeonmed - The Operating Expert of OR&ICU
In 2008, one anesthesia machine designed and made by Aeonmed was successfully launched in the US market which made a breaking through for the Chinese anesthesia manufacturers. So far Aeonmed's products have been sold to more than 120 areas and countries, and 61 products have received the CE certificate. We are proud that one of our emergency ventilator, Shangrila 510, was selected among almost the most famous brand around world as standby support for emergency use on every event spot, the total number was 175 units. In June 2013, Aeonmed’s intensive care ventilator gains the access to the US market. It is milestone of ventilator business developing in China.
Independent innovation built Aeonmed's competitive ability. To date, over 800 patents have been approved or applied, including over 500 invention patents. Aeonmed maintaining a substantial annual increase of more than 100 patents.
"Reliable Quality, Thoughtful Service” is Aeonmed’s commitment to customers”, and “Guard life sincerely" is the sacred mission of Aeonmed.
Facing the future, Aeonmed people are working enthusiastically towards company's vision – to be "the Operating Expert of OR & ICU".
Products Introduction:
Packaging and shipping
Contact Person : | Ginny |
---|